PVC-Free Film by the Numbers: Width, Roll, Thickness, Peel
Quick answer
Six numbers decide whether a decorative film can be specified: width, roll length, thickness, tensile strength, peel adhesion and the temperature window. On this PVC-free range width is 1220 mm nominal, rolls are 25 or 50 m, thickness runs 0.15 to 0.25 mm with an eight percent tolerance that follows texture depth. Tensile is 25.0 MPa machine direction and 20.0 MPa across. Peel is 20 N per inch minimum, tested at 27 N on GB/T 2792-2014. Installation wants 10 to 35 degrees Celsius, service range indoors is minus 10 to 50, and shelf life is one year from production. Everything else is a texture choice. PVC-free, PP-based film. Read together, they answer the three questions that decide a tender: how many drops per wall, how much waste per room, and whether the bond survives the substrate that is actually on site.
Specification sheets fail in a predictable way: they list twenty properties, and the buyer cannot tell which six decide the outcome. Here are the six, with the reason each one earns its place.
1. Width, and why it is not 1260
Finished width is 1220 mm nominal. The 1260 mm figure that appears in some documents is the raw film width before processing; it is not the roll you receive. On a wall 3.6 m high, 1220 mm means three drops with a 180 mm trim allowance, not two and a half.
2. Roll length drives the waste calculation
Rolls come in 25 m and 50 m nominal. Choose on drop count, not on price per roll: a 50 m roll halves the number of times an installer climbs down, but only if the room is big enough to consume it without leaving a half roll that hardens on the shelf.
3. Thickness is a range, not a number
0.15 to 0.25 mm, plus or minus eight percent. Deep emboss needs more material than a flat colour, so quoting one figure across a range guarantees a rejection at goods-in. Quote the band, and tie the band to the texture in the order line.
4. Tensile strength tells you about handling
MD 25.0 MPa minimum, TD 20.0 MPa minimum. This is about surviving installation, not about the wall. A film that tears when a corner is pulled is a labour problem that shows up as an aesthetic problem a month later.
5. Peel adhesion is the warranty question
| Substrate (24 h) | Measured peel |
|---|---|
| Painted wall | 26.8 N |
| Gypsum board | 24.3 N |
| Aluminium composite | 35.3 N |
| Stainless steel | 39.4 N |
| Glass | 39.1 N |
The specification floor is 20 N per inch minimum, tested at 27 N on GB/T 2792-2014. Note the wording: the tested value is evidence, not a guaranteed minimum. Write the floor into the tender and keep the test value as supporting documentation.
6. The temperature window, both halves
Installation wants 10 to 35 degrees Celsius. Service indoors is minus 10 to 50. The installation half is the one that gets ignored, and it is where winter projects fail: adhesive that will not wet out at 6 degrees does not become a warranty claim at 20, because the bond was never formed.
What is deliberately missing
Shelf life is one year from production, which is why the batch date belongs on the delivery note. Beyond that, this sheet says nothing about colour permanence under a particular light source, or about fire performance - both need their own document, and neither should be inferred from the base chemistry.
The range itself: D1500 PVC-free line. Texture families: finishes. Sampling: how samples are shipped.
Specifying this for a project?